The GE Cardiac Assessment for Exercise Testing (CASE) stress test monitor offers users a number of options which allow the monitor to adapt to your unique needs. The GE CASE offers users greater diagnostic confidence by easily and accurately view cardiac function during intensive exercise. This system includes on-site training for all office employees, allowing users to better take advantage of our industry leading algorithms. The GE CASE stress test monitor is compatible with Marquette T2000 and T2100 treadmills. All GE CASE Plus stress test monitors include a one-year manufacturer warranty.

Additional features and benefits of the GE CASE system include, but are not limited to, the following:


  • Tools for diagnoses and analyses

  • Diverse and easily configured system

  • Capable of integration with T2000 and T2100

  • One-year manufacturer warranty

  •  


    CLICK HERE FOR GE CASE ACCESSORIES


     

     

    Product Reviews

    Write a Review for this Product

    Rating
    Your Review
     

    Product files

    GE Case 6.6 & DICOM Product Sheet
    GE CASE 6.6 Networking Product Sheet

    GE Case V 6.7 Specifications

      Singal Processing:
    • ECG Analysis Frequency: 500 Hz
    • ST Measurements: ST amplitudes, slope, integral, index, ST/HR slope, ST/HR loops, ST/HR index up to 15 leads
    • E, J and Post-J Point: Manual or computer selected
    • Signal Processing: Incremental median updating technique
    • Baseline Correction: Finite Residual Filter (FRF) and/or Cubic Spline analysis
    • QRS Detection and Analysis: Automatic or manual lead selection
    • ECG Output: Real-time ECG/QRS beep/TTL synchronization output
    • Heart Rate: Automatic arrhythmia detection, documentation and annotation
    • Full-Disclosure ECG: Beat-to-beat ECG storage & event review
    • Reanalysis: Post-test medians measurements from E, J and post-J point selections
    • ECG Interpretation (Optional): Marquette* 12SL* resting ECG analysis program for adults and pediatrics
    • Additional ECG Function: XTI stress interpretation; Vectorcardiography (15 lead)

    • Data Aquisition:
    • Technology: Active, “Type BF” floating isolated powered 14-channel acquisition module with built-in lead-fail detection and lead prep impedance measurement
    • Sampling Rate: Over-sampling @ 4000 Hz
    • Dynamic Range: 320 mV, ± 10 mV signal superimposed on ± 150 mV DC offset
    • Resolution: 4.88 μV/LSB @ 500 Hz
    • Noise: < 15 μV peak-to-peak noise over 0.01 to 150 Hz (-3 dB) bandwidth
    • Frequency Response: -3 dB, display and writer
    • High-Pass Filter: 0.01 (or 0.05 Hz, special use) with DC offset control
    • Low-Pass Filter: 20, 40, 100, 150 Hz (selectable)
    • Line Filter: 50.0 or 60.0 Hz notch filter (selectable)
    • Baseline Correction: Cubic Spline algorithm
    • Artifact/Baseline Correction: Finite Residual Filter (FRF) analysis
    • Common Mode Rejection: > 140 dB (123 dB with AC filter disabled)
    • Input Impedance: > 10 M Ohms @ 10 Hz, defibrillator protected
    • Patient Leakage: < 10 μA
    • Pace Detect: Orthogonal LA, LL and V6; 750 μV @ 50 μs

    • Communications/Storage Options:
    • MUSE* systems compatible via diskette; network (optional)
    • MUSE Web compatible for retrieval view and printing of MUSE system data
    • Local storage: Minimum 40 GB hard drive storage of complete ECG record and test results
    • PDF export of final reports with auto naming protocols also from Microsoft® Word and Excel
    • XML export of specified data
    • CASE* network server with editing workstations
    • Windows® XP operating system

    • Display:
    • Display Type: LCD (flat panel display)
    • Display Resolution (Minimum): LCD-1280 x 1024
    • Display Size: 17 or 19-inch LCD
    • Monitored Leads: 3, 6, 12 or 15
    • Displayed Leads: Number on screen 3, 6, 12 or 15
    • Display Format: 3 rhythm, 3 rhythm + medians, 3 rhythm + trends, 6 rhythm, 4 x 2.5 + 1 rhythm, 2 x 6
    • Display Speeds 25, 50 mm/s
    • Display Sensitivity/Gain: 2.5, 5, 10, 20 mm/mV
    • Displayed vital Signs Data (Configurable): Heart rate, target heart rate, blood pressure, exercise clock, stage clock, phase clock, protocol, speed, grade, Watts, METS, RRP and SpO2
    • Displayed data ST scan/median complexes, arrhythmias, ventricular ectopic/min counter, 3 to 12 lead waveforms, lead check torso and 12 leads, waterfall display, trends, tabular summary, stored ECG strips, interpretation, time-of-day clock, patient name, warning messages and prompts

    • Writer:
    • Writer Technology: “Instant” load, thermal dot array
    • Writer Leads: 3, 6, 12 or 15 leads (standard, NEHB, Cabrera, configurable)
    • Writer Speeds: 5, 12.5, 25 and 50 mm/sec (± 2%)
    • Writer Sensitivity/Gain: 2.5, 5, 10 or 20 mm/mV (± 5%)
    • Writer Resolution: Horizontal 1000 lines/sec x 200 dpi dedicated local printing. 200 x 200 dpi generic printing
    • Paper Type: Thermal, perforated, fan-fold, 300 sheets/pack
    • Paper Size: A size 214.63 x 280 mm (8.45 x 11 in); A4 size 210 x 297.5 mm (8.27 x 11.0 in)

    • Physical Specifications:
    • Height: 148 cm (58 in) with no monitor installed
    • Width: 62 cm (24 in) with paper tray removed
    • Depth: 75 cm (30 in)
    • Weight 68 kg (150 lb) without monitor

    • Minimum Server Requirements:
    • Microprocessor: Pentium® ! 1.6 GHz
    • RAM: 256 MB
    • Hard Drive: > 40 GB
    • Operating system: Windows 2000 Server; Windows 2003 Server

    • Interfaces Included:
    • Acquisition module
    • Keyboard (PS/2) anti dedicated stress keypad (USB)
    • Mouse (PS/2)
    • Built-in thermal printer (USB)
    • 100 Mbps ethernet MUSE compatible
    • 6 serial ports: (COM 1-2, COM A-D) treadmill, BP, ergometer, SpO2
    • 4 analog and 1 TTL (trigger) output analog ergometer, camera sync, etc.
    • Diskette drive: 3 1/2 in, 1.44 MB
    • PC-compatible for data storage
    • CD-R/W drive: readable for software updates; archivable data optional

    • Electrical Power:
    • Power Supply: AC operation only
    • Operating voltage range 100-120 VAC, 50-60 Hz, 2.8 A; 200-240 VAC, 50-60 Hz, 1.4 A
    • Power consumption 350 W max (1200 BTU/hr); < 250 W normal (850 BTU/hr); < 30 W standby (100 BTU/hr)

    • Opperating Conditions:
    • Temperature: +10 to 40°C (+50 to 104°F)
    • Humidity: 20 to 95% RH non-condensing

    • Storage/Transport Conditions:
    • Temperature -40 to +70°C (-40 to 158°F); Paper discoloration may occur at high temperatures
    • Humidity: 15 to 95% RH non-condensing