GE Dash 2500 v4 Monitor GEN-VIT-2042676-002
  • GE Dash 2500 v4 Monitor GEN-VIT-2042676-002
  • Dash-2500-Shadow.gif
Click image for larger view | Use arrows to view more images

GE Dash 2500 v4 Monitor

GEN-VIT-2042676-002

The GE Dash 2500 monitor is a dependable, cost-effective bedside monitor that gives you the clinical intelligence you need to assess and treat your patients with speed, accuracy and attention. 
 
Just because the monitor is cost-effective, does not mean it is any less sophisticated or durable. The monitor includes clinical parameters to capture vital patient measurements and exceptional cardiac monitoring to help accurately detect arrhythmias. The Dash 2500 is designed for demanding clinical environments. Its durability will be well suited in any working environment. It is also chemically resistant; therefore powerful cleaners will not damage the monitor. 
 
The GE Dash 2500 monitor is user friendly and easily configurable to suit your viewing preferences and information requirements. The monitor’s compact size and weight make the Dash 2500 easily portable. You are able to transfer patients throughout the facility and maintain an uninterrupted flow of data. The monitor also offers a long battery life. 
 
Davis Medical Electronics offers two options of the GE Dash 2500 monitor, refurbished or new. 
 

Dimensions:
  • Height: 8.7 in/22 cm
  • Width: 14.1 in/35.8 cm
  • Depth: 6.7 in/17 cm
  • Weight: 12 lbs/5.5 kg

  • Environmental:
  • Operating Temperature: 5°C to 40°C (41°F to 104°F)
  • Storage Temperature: [-20]°C to 60°C (-4°F to 140°F)
  • Operating Humidity: 5 to 95% non-condensing
  • Storage Humidity: 5 to 95% non-condensing
  • Operating Atmospheric Pressure: 700 to 1060 hPa
  • Storage Atmospheric Pressure: 500 to 1060 hPa

  • Electrical Power:
  • AC Input Voltage: 100 to 240 V
  • AC Input Frequency: 50/60 HZ
  • AC Input Power: 120 VA
  • Internal Battery: 8.4 V nickel metal-hydride (NiMH)
  • Power Supply: Can be powered from the internal battery or AC power

  • Battery:
  • Capacity: 8.4 V; 7.0 amp per hour
  • Battery Life: Greater than 180 minutes using fully charged internal battery (NIBP: five min auto cycle with adult cuff. ECG, RESP, SpO2: Active. TEMP: predictive mode. Printer: printing two waveforms for one min every 20 min at 25 mm/sec)
  • Charge Time: 4 hours maximum with the Monitor switched OFF; 8 hours maximum with the Monitor switched ON

  • Heart Rate/Pulse:
    Electrocardiography (ECG):
  • Heart Rate Accuracy: 30 to 300 bpm, ± 3 bpm or 3% of reading, whichever is greater

  • Nellcor SpO2:
  • Range: 20 to 250 bpm
  • Accuracy/Tolerance: 20 to 250 bpm ± 3 digits
  • Low Perfusion: 20 to 250 bpm ± 3 digits

  • Masimo SpO2:
  • Range: 25 - 240 bpm
  • Accuracy Without Motion: 25 - 240 bpm ± 3 digits
  • Accuracy With Motion Tolerance: Normal physiologic range, 25 to 240 bpm ± 5 digits

  • Non-Invasive Blood Pressure (NIBP):
  • Adult/Pediatric Range: 30 - 200 bpm
  • Neonate Range: 30 - 220 bpm
  • Accuracy: ± 3.5% or 3bpm, whichever is greater

  • ECG:
  • 3 Lead Electrode Configuration: I, II, III
  • 5 Lead Electrode Configuration: I, II, III, aVR, aVL, aVF, and VA
  • Heart Rate Accuracy: 30 to 300 bpm, ± 3 bpm or 3% of reading, whichever is greater
  • Heart Rate Resolution: 1 bpm
  • Bandwidth: 0.5 to 40 Hz +1/-6 dB
  • 0.05 to 40 Hz +1/-6 dB
    0.05 to 100 Hz +1/-6 dB
  • Standardizing Voltage: 1 mV marker
  • Common Mode Rejection: 1 mV RTI or 10 mm p-p max displayed noise allowed with 20 Vrms, 50-60 Hz input
  • Common Mode Input Impedance: > 2.5 MΩ at 10 Hz
  • Differential Input Impedance: > 2.5 MΩ from DC to 60 Hz
  • 60 Hz Tolerance: Up to 10 mV
  • Pacemaker Detection/Rejection Input Voltage Range: ± 2 to ± 700 mV
  • Lead off sensing current < 0.1 μA DC signal leads; < 1 μA DC driven lead

  • Respiratory:
    ECG-Derived respiration rate:
  • Leads Available: I or II
  • Range: 6 to 120 breaths/min (adult/pediatric); 6 to 180 breaths/min (neonate)
  • Accuracy: ± 2 breaths/min or ± 3% of reading, whichever is greater
  • Resolution: 1 breath/min
  • Base Impedance: 100 to 2000 Ω
  • Detection Sensitivity: 0.2 Ω at 30 breath/min with 500 Ω baseline impedance

  • NIBP:
  • Method: Oscillometric with step deflation
  • Modes: Manual, automatic, stat

  • BP Measurement Ranges:
  • Systolic: 30 to 290 mmHg (adult/pediatric)
  • 4.0 to 38.7 kPa (adult/pediatric)
    30 to 140 mmHg (neonate)
    4.0 to 18.7 kPa (neonate)
  • MAP: 20 to 260 mmHg (adult/pediatric)
  • 2.7 to 34.7 kPa (adult/pediatric)
    20 to 125 mmHg (neonate)
    2.7 to 16.7 kPa (neonate)
  • Diastolic: 10 to 220 mmHg (adult/pediatric)
  • 1.3 to 29.3 kPa (adult/pediatric)
    10 to 110 mmHg (neonate)
    1.3 to 14.7 kPa (neonate)
  • Resolution: 1 mmHg
  • Accuracy: Meets AAMI/ANSI standard SP10:2002
  • Initial Cuff Inflation Pressure: 135 ± 15 mmHg default; user selectable (adult/pediatric) 100 ± 15 mmHg default; user selectable (neonate)
  • Maximum Determination Time: 120s (adult/pediatric); 85s (neonate)
  • Over Pressure Monitor: 300 to 330 mmHg (adult/pediatric); 150 to 165 mmHg (neonate)
  • Hose/cuff Interface: Compatible with current Dash hoses
  • Pulse Rate: When NIBP is the source, HR values are derived from the pulse rate that is determined by the oscillometric technique of measuring blood pressure. The rate source field is labeled NIBP.
  • Adult/Pediatric Range: 30 to 200 bpm (± 3.5% or 3 bpm)
  • Neonate Range: 30 to 220 bpm (± 3.5% or 3 bpm)

  • Nellcor OxiMax SpO2:
    Measurement Range:
  • SpO2: 1 to 100%
  • Pulse Rate: 20 to 250 bpm
  • Saturation Accuracy: Adult: 70 to 100% ±2 digits
  • Neonate: 70 to 100% ±3 digits
    Low Perfusion: 70 to 100% ±2 digits
  • Adult and Neonate Pulse Rate: 20 to 250 bpm ±3 digits
  • Low Perfusion Pulse Rate: 20 to 250 bpm ±3 digits

  • Masimo SET SpO2:
    Measurement Range:
  • SpO2: 1 to 100%
  • Pulse Rate: 25 to 240 bpm

  • Accuracy and Motion Tolerance:
  • Saturation: Without Motion–Adult/Pediatric:70 to 100% ±2 digits
  • Without Motion–Neonate: 70 to 100% ±3 digits With Motion–Adult/Pediatric/Neonate: 70 to 100% ±3 digits Low Perfusion: 70 to 100% ±2 digits, 0 to 69% unspecified
  • Pulse Rate: Without Motion: 25 to 240 bpm ±3 digits
  • With Motion: Normal physiologic range 25 to 240 bpm ±5 digits

    Alaris Turbo Temp:
    Predictive Mode:
  • Range: 35.6°C to 41.1°C (96.0°F to 106.0°F)
  • Resolution: 0.1°C (0.1°F)

  • Monitor Mode:
  • Range: 26.7°C to 42.2°C (80.0°F to 108.0° F)
  • Accuracy: ± 0.1°C (± 0.2°F) (when tested in a calibrated liquid bath; meets ASTM E1112, Table 1, in range specified)
  • Resolution: 0.1°C (0.1°F)
  • Probes: Use only Alaris Turbo Temp probes and probe covers. The size, shape, and thermal characteristics of the probe covers can affect the performance of the instrument. Inaccurate readings or retention problems may occur unless Alaris Turbo Temp probes and probe covers are used
  • Determination Time: Approximately 10 seconds, typical
  • Recommended Products