EchoPAC™ Software Only is a comprehensive clinical software package for viewing, analyzing and reporting of multi-dimensional echo, vascular and abdominal ultrasound images. EchoPAC Software Only provides basic and advanced viewing and quantitative analysis capabilities for 2D, 4D and multi-dimensional ultrasound parametric images from the GE Healthcare Vivid™ family of scanners, as well as DICOM® images from other ultrasound systems.
 
Additional features and benefits of the GE EchoPAC software include, but are not limited to, the following:

  • GE EchoPac software can be used with your laptop or PC
  • Q-analysis, Stress and advanced stress, MPEGvue, DICOM and EchoDICOM    
  • Qualitative analysis is performed quickly, reports are created and images are stored directly from your workstation, thus freeing your Ultrasound for additional patients
  • TruData allows you to transfer data from your ultrasound to your PC
  • Advanced 4D analysis and Toolkit includes 4D Auto LVQ, 4D LV Mass, 4D Strain
  • AFI: Automated Function Imaging
  • Tissue Velocity imaging capabilities
  • Echo and Vascular Reporting

Ease of Use

  • Measurements from Vivid 7, Vivid i, Vivid q, Vivid S5, Vivid S6, Vivid T8, Vivid E7, Vivid E9, Vivid S70, Vivid E90 and Vivid E95 populate the EchoPAC report from the EchoPAC worksheet.
  •  Physicians decide which measurements will be displayed on the final report.
  • The sonographer or physicians on the fly can customize templates for echo, vascular and stress reports without system programming experts

Physical Product

  • Installation CD
  •  User manual
  •  Installation manual
  •  Container box
  •  Option key (password)
  •  Dongle for licensing (USB)

Measurements and Analysis

  • Measurements can be labeled seamlessly by using protocols or post assignments
  • Parameter annotation follow ASE standard
  • Seamless data storage and report creation
  • Comprehensive set of cardiac measurements and calculations to help assess dimensions, flow properties and other functional parameters of the heart
  • Comprehensive set of shared service measurements and calculations covering vascular, abdominal, obstetrics and other application areas
  • Configuration package to set up a customized set and sequence of measurements to use, defining user-defined measurements and changing settings for the factorydefined measurements
  • Stress echo support allowing wall motion scoring and automatic stress level labeling of measurements
  • Support for measuring DICOM images
  • Automatic Doppler trace functionality for use in non-cardiac applications in both live and replay
  • Parametric imaging tool which gives quantitative data for global and segmental wall motion

AFI stress echo

  • Single or triplane acquisition of standard 2D apical views
  • Analysis with dedicated AFI stress analysis tool
  • Provides longitudinal strain values per segment, as well as globally
  • Allows complete assessment at a glance by combining three longitudinal views into one comprehensive bulls-eye view
  • Integrated into M&A package with specialized report templates
  • Simplified workflow with adaptive ROI, quick tips and combine display of traces from all segments

Functionality

  • Review of stress-echo studies acquired with the Vivid 7, Vivid i, Vivid q, Vivid S5, Vivid S6, Vivid T8, Vivid E9, Vivid S70, Vivid E90 and Vivid E95, as well as other DICOM ultrasound systems
  • Quantitative stress analysis of grayscale 2D and tissue velocity information raw data acquired in parallel on
  • Qualitative wall motion scoring
  • Quantitative stress analysis provides three different analysis tools based on TVI data stored during stress acquisition.
  • Vpeak measurement: Enables the display of a tissue velocity trace for a selected region of a previously
    scored segment through the entire heart cycle
  • Quantitative analysis package- Traces for velocity or derived parameters (strain rate, strain, displacement) inside defined regions of interest as function of time

DICOM

  • Storage
  • Read/write images on DICOM format
  • (US, US-MF and Secondary Capture)
  • Storage Commit (SC)
  • Query/retrieve
  • DICOM print
  • DICOM SR creation

EchoPac 204 HW specifications:

  • Windows 10 required
  • I7 2.0 GHz or greater processor that supports SSE4.2 and AVX
  • 32 GB RAM or greater recommended, 16 GB (minimum)
  • 1 TB HD, 500 GB minimum

Nvidia graphics card, models listed in the attached document or any other model that meets the following parameters:

  • Shader 5.0 or greater
  • Discrete DirectX 11 or greater
  • CUDA 2.3 or greater
  • 4 GB VRAM or greater recommended, 2 GB (minimum)
  • Minimum 2 USB ports
  • CD/DVD drive/burner
  • (2) color monitors screen
 