The GE Mac 3500 ECG is one of the finest in GE’s line of resting electrocardiograph systems. The GE Mac 3500 offers users the best technology on a 12 lead ECG analysis system. GE Mac 3500 is among the most user-friendly electrocardiographs available, allowing users to focus less on operating the system and more on your patients.
In addition, the GE Mac 3500 is an affordable electrocardiograph! Other features and benefits of the Mac 3500 include:
- 90 Day Warranty
- 12 lead recorder with analysis
- Flexible and scalable
- User interface common with MAC 5500
- Integrated ECG acquisition module
- Integrated pump for KISS system
- Pacemaker detection
- 12SL ECG analysis program
- New Battery and cables included
Display Screen:
6.5 in (165 mm) diagonal graphics backlit AM LCD (color optional)
640 x 480 pixels with waveform enhancement
Data: Heart rate, patient name, ID, clock,
waveforms, lead labels, speed,
gain and filter settings, warning
messages, prompts, and help
messages. 6 leads maximum.
Dimensions:
Height: Approximately 7.6 in (19.3 cm)
Width: Approximately 15.6 in (39.6 cm)
Depth: Approximately 15.0 in (38.1 cm)
Weight: Approximately 7.0 kg (15.5 lbs), including battery, without paper
Electrical Power:
Power supply: AC or battery operation
Voltage: 100 to 240 VAC +10, –15%
Current: 0.5A @ 115 VAC, typical; 0.3A @ 240 VAC, typical
Frequency: 50 to 60 Hz ±3Hz
Battery Type: User replaceable, 18V @ 3.5 AH
±10% rechargeable NiMH
Battery Capacity: 100 single page reports, (typical)
or 6 hours continuous display
(without printing)
Battery Charge Time: Approximately 4.5 hours from total
discharge (with display off)
Processing:
ECG Interpretation: Marquette 12SL ECG Analysis
Program for Adults and Pediatrics
Computerized Measurements: 12-lead analysis
ECG Analysis Frequency: 500 samples/second (sps)
ECG Storage: 50 ECGs in internal memory
External Archiving: Optional secure digital card for 50 ECGs max; Supports 64 MB to 1 GB SD cards
Digital Sampling Rate: 4,000 samples/second/channel
Pre-acquisition: Provides 10 seconds of instantaneous ECG acquisition
Dynamic Range: AC Differential ± 5mV, DC offset ±300 mV
Resolution: 4.88 μV/LSB @ 250 sps; 4.88 μV/LSB @ 500 sps
Frequency Response: [–3] dB @ 0.01 to 150 Hz
Common Mode Rejection: >140 dB (123 dB with
AC filter disabled)
Input Impedance: >10MΩ @ 10 Hz,
defibrillator Protected
Patient Leakage: <10 μA
Pace Detect: Orthogonal LA, LL, and V6;
750 μV @ 50 μs
Special Acquisition Functions: Disconnected lead detection,
electrode impedance, excessive
AC noise, baseline wander and
muscle tremor messages
Heart Rate Meter: 30 to 300 BPM ±10% or 5 BPM,
whichever is greater. Heart rates
outside this range will not be
displayed.
Writer:
Writer Technology: Thermal dot array
Writer Speeds: 5, 12.5, 25, & 50 mm/s
(same as displayed)
Number of Traces: 3, 6, or 12 user selectable
(same as displayed)
Writer Sensitivity/Gain: 2.5, 5, 10, 20, 10/5 (split calibration)
mm/mV (same as displayed)
Writer Speed Accuracy: ±10% at 5 & 12.5 mm/s;
±2% at 25 & 50 mm/s
Writer Amplitude Accuracy: ±5%
Writer Resolution: Horizontal 1000 dpi @ 25 mm/s,
200 dpi vertical
Paper Type: Thermal, Z-fold, perforated,
fan fold, 300 sheets/pack
Paper Size: A Size: 8.45 in x 11 in,
(214.63 mm x 280 mm);
A4 Size: 8.27 in x 11.7 in
(210 mm x 297.5 mm)